In order to understand the levels of acoustic impact that Gym activities were likely to create within the adjacent sensitive spaces, detailed acoustic feasibility testing was undertaken within the unit. The tests involved measurements of radiated noise and vibration impacts on the adjacent spaces from dropping of weights, and determining the nature and extent of acoustic flooring treatments required to mitigate impacts from the adjoining uses.
Similar tests were also undertaken on the internal and external building fabric elements to determine suitable acoustic mitigation measures necessary to control noise transfer and breakout from the Gym
Based on the results of the detailed in-situ testing, a detailed report was provided to PureGym to highlight the acoustic risks of the site and to provide detailed mitigation measures to maintain the acoustic amenity of the adjacent sensitive uses.